Command: |
Load from 1 to 25 records of solicitation data to user storage. |
|
Notes: |
The command can be used repeatedly to load the solicitation data. It overwrites any tables or keys stored in the user storage. Therefore, it is necessary to reload the tables and keys when solicitation processing has been completed. This command will not operate in an ESCON connected HSM due to limitations of the channel protocol. To use PIN solicitation functions in ESCON connected HSMs the Final Load (QC) command must be used. |
|
Field |
Length & Type |
Details |
|
COMMAND MESSAGE |
||
|
Message header |
m A |
(Subsequently returned to the Host unchanged). |
|
Command code |
2 A |
Value QA. |
|
Solicitation Data 1 |
n A |
The 12-digit reference number. The selected PIN (4 to 12 digits). A semicolon “;” as a delimiter. |
|
Solicitation Data 2 |
n A |
The 12-digit reference number. The selected PIN. A semicolon “;” as a delimiter. |
|
. |
. |
. |
|
. |
. |
. |
|
. |
. |
. |
|
Last solicitation data |
n A |
The 12-digit reference number. The selected PIN. A semicolon “;” as a delimiter. |
|
End message delimiter |
1 C |
Optional. Must be present if a message trailer is present. Value X’19. |
|
Message trailer |
n A |
Optional. Maximum length 32 characters. |
|
RESPONSE MESSAGE |
||
|
Message header |
m A |
Returned to the Host unchanged. |
|
Response code |
2 A |
Value QB. |
|
Error code |
2 N |
00 : No errors 15 : Error in input data 30 : Invalid reference number |
|
End message delimiter |
1 C |
Present only if present in the command message. Value X’19. |
|
Message trailer |
n A |
Present only if present in the command message. Maximum length 32 characters. |